Inspection and maintenance of control cabinet of full-automatic unburned brick machine


The control cabinet of the fully automatic unburned brick machine will encounter some small problems in the use process. During the use of the cement brick machine, the brick machine should be well maintained. For example, the distribution cabinet of the brick machine should also be regularly inspected and maintained.

The full-automatic or semi-automatic unburned brick machine equipment is equipped with corresponding power distribution cabinet. As the central control component, the power distribution cabinet is rich in many electronic components, so it sometimes presents some problems. However, according to the calculation, many problems of the power distribution cabinet are caused by the operator’s mistakes, which can be avoided. Now let’s introduce how to protect the power distribution cabinet very well in the process of operating the unburned brick machine equipment.

1. Each time you start the machine, you should first check whether the power supply is properly connected. The power supply is 380V three-phase four wire AC power supply. Close the circuit breaker of the electric control cabinet, check whether the voltage displayed on each voltage is normal, and check whether the PLC, text display device and limit switch are damaged or loose.

2. The plate receiving machine, material distributing machine, plate coding machine and these knobs are all activated to the position and stop automatically. The dialer, down vibration and these knobs are pressed and released to stop (emergency stop and manual/active knobs are outside).

3. Clean the text displayer without gloves, and do not scratch or strike the screen with hard objects.

4. In case of thunderstorm weather, production shall be stopped and all power supplies shall be closed. The electric cabinet shall be well grounded

微信图片_202109131710432